Lightweight.
Clear.
Min.
Nom. Thickness:
3"
Asb 0.80mm (0.032")
Fire
Ratings
BS
Superweight Vistalux is class O as defined by
Appendix A, Approved document B, 1992 Buildings
regulations. Heavy duty and light duty Vistalux
are Class 1(BS 476 Part7). All Vistalux sheets
are classified "self-extinguishing" when tested
to Method 508A pat 5 BS 2782.
KENT's
10 YEAR GUARANTEE
Kent
Plastics Ltd., undertakes to supply
a replacement free of charge for any
Vistalux PVC sheet that proves to
have failed due to a manufacturing
defect, in normal weather conditions,
during a period of 10 years from the
date of purchase.
This
guarantee is only valid providing
the Vistalux has been fixed in accordance
with the manufacturers' instructions
and does not extend to the cost of
re-erection or other consequential
loss.
This
guarantee is offered as an extra benefit
and does not affect consumers' statutory
rights.
|
Fixing
Instructions
Sheets
must not be stacked in direct sunlight or
distortion and discolouration will occur, due
to the serveral thicknesses acting as a magnifying
glass and causing heat build up within the stack.
If left in the open, sheets should be covered
with an opaque(not black) tarpaulin. Stack height
should not exceed 1.22m(4'0") and should be
supported on 2" battens, not more than 3' apart.
Cut
sheets singly or several together over a firm
support. Use a fine tooth saw at a low angle.
If 'binding' occurs the saw can be lubricated.
Care should be taken in handling and cutting
in very cold weather. Extreme caution is recommended
at temps below 4.5degrees Centigrade(40 Fahrenheit).
Drill sheets singly or several together, preferably
over a firm support using a hand or slow speed
power drill and a masonry bit. Holes should
be 2mm(1/16") oversize the fixing screw or bolt.
Never punch holes through the sheets;all holes
must be pre-drilled prior to nailing. Always
use Ariel fixings comprising screws, washers,
caps and for better support use Ariel Super
Fixings(See profile diagram and Purlin Centres).
When lapping ends of sheets the minimum lap
should be 150mm (6"). But where the roof slope
is less than a 10 degree a 12" overlap is recommended.
Never leave inadequately fixed sheets on unfinished
jobs. Fixings should not be overtightened and
no nearer ends of sheets than 50mm(2"). A false
ceiling must not be erected below the Vistalux
as this will cause heat to build up which will
discolour or distort trhe Vistalux sheet.
Wind
Loading. Where sheets are to be used on
buildings subject to high wind loadings, or
other unusual conditions, please refer to the
technical advisors.
Flashing.
Where Vistalux sheet meet a wall, the gap
should be sealed wiht Clear PVC flashing and
flat aluminium flashing or rpeformed aluminium
flashing.
Eaves-Fillers.
Available to suit all profiles, Insert at
eaves and ridge to give a weather-tight seal
and a neat finish.
Sealing
Tapes. Available to suit all profiles, Insert
between lapped sheets to provide a realiable
seal against dust and dirt.